NCR 5877

The Personas 77 makes sure you
achieve that business advantage.
Designed to offer service in spaceintensive
environments, such as lobbies,
vestibules or stores, the Personas 77
combines efficient construction with
enormous opportunity.

Specifications

Multimedia Interface
15" CRT color screen
Optional advert light panel
8 tactile function display keys
Ruggedized tactile 16 key keyboard
Dip or motorized card reader with smart card     
option
EMV 3.1.1 compliant smart card reader                                               
Private audio system
Software video
Printer Specification
RECEIPT PRINTER
40 column graphics printer
Capacity up to 5000 transactions 4.4" (112mm)
receipts
Form length 4.4-7.5" (112-190mm)
Optional sideways feature allows 80 column x 20
row mini statement
JOURNAL PRINTER
40 column graphics thermal or dot matrix
printer
Capacity up to 5000 @ 5 line journal entries
Technical Specifications
PLACEMENT
Front, rear or vestibule access
PRODUCT DIMENSIONS
Height - 59.43" (1507.65mm)
Pavement to apex of fascia
Height - 57.3" (1455mm)
Pavement to top box
Width - 18.5" (470mm)
Depth - 28.8" (726.5mm)
Weight - max. 1071lbs (486kg) CEN A3 security
Weight - min. 408lbs (185kg) UL 291 Business
hours
DISPENSER
1,2,3 or 4 denomination options with bunch
(retract)
1,2 or 3 denominations options with spray
NCR universal polycarbonate multimedia
cassette with 11.6" (295mm) capacity
SECURITY
Physical
UL 291 Business hours
UL 291 Level 1
CEN Grade A3
 
INFORMATION
HI-BAPE (DES)
EKC (DES, RSA limited to initial key exchange),
enhanced physical protection
ELECTRONIC PLATFORM
Pentium® III processor
ACCESSIBILITY
Subject to compliance with NCR site preparation
and installation guidelines, the NCR P77
complies with ADAAG 4.34.2, 4.34.3, and 4.34.4.
NCR cannot certify or warrant compliance with
ADAAG 4.34.5.
ELECTROMAGNETIC COMPATIBILITY
Emission
FCC Category A (USA)
EN 55022 (1987) Class A
VDE 0871/75 Class A
CISPR 22 Class A
Immunity
EN 50082-1 Part 1 (1992)
Generic Immunity Standard
Radiated Immunity – IEC 801-4-3
Electrostatic Discharge- IEC 801-4-2
Fast Transients – IEC 801-4-4
EMC Directives
89/336/EEC EMC Directive
92/31/EEC Amending EMC Directive
73/23/EEC Low Voltage Directive
SAFETY HOUSE COMPATIBILITY
UL 291
CAN/CSA – C22.2 no. 950 EN60 950
ENVIRONMENTAL
Operating temperature: 50°F (10°C) to 104°F
(40°C)
Relative humidity: 20% to 80%
ACOUSTICS
Sound power: max 55 dBA idle, 60 dBA
operating
Sound pressure: 55 dbA operating